Windows Software

MTWin-5

supports USB Interfaces!

  • MTWIN-5 is used for exchanging data between data capturing device and PC.
  • Supports aitronic data capturing devices, which are connected via RS-232, LAN or USB.
  • The batch-enabled version MTW is included in the installation file.
  • Runs under Windows 7/8/10.
Communication Software
  • MTWin-5

    Communication software for the data exchange between mobile terminals and Windows PC. Starting with Version 4.0 MTWIN supports USB interfaces (i.e. for LogiScan-1100). MTWIN-5 replaces MTWIN-3 and MTWIN-4. Runs under Windows XP/2000/Vista/7/10. Version: 5.11, Datum: 02.09.2016

LogiScan-600/800/1100 MTWin-5

How can I transfer the data received from MTWin-5 into any Windows application?

Using the AutoHotkey Open Source software and a script, you can transfer the data received by MTWin-5 into any Windows application. The demonstration software AutoHotkey Demo for MTWin shows how to do that.

How can I set the name and destination directory for the transferred data?

The transmission option can be selected for the receive file between "Collection File" (the data of all devices are collected in file MTWin.txt) and "Generation with Serial Number" (for each device a separate file is created).

Under Option→Directories, target directory and file name can be set for the received data. Different placeholders (for serial number, station number, date and time) can be used to generate the file name. In this way, it is possible to create a unique file name for each data transfer (detailed description contains the MTWin-5 manual).

A destination path given in the STX line at the beginning of the data transmitted by the mobile terminal replaces the destination path settings made in MTWin-5 and allows the transferred data to be stored in any different directories.

How can I re-transfer data already transferred?

In order to be able to transfer data already transmitted, the data on the device may not be erased by MTWin-5 after the data transmission, but must only be marked as "already transmitted" (MTWin-5 function option> Transmission> after data reception> transmission Lock). For a new data transmission, the "MTWin-5" function must be used to clear the "Utilites→Clear Transmission Lock" function. Subsequently, the data can be retransmitted.